SAFETY-CRITICAL PSU FIXES:
- Removed Dell D220P-01/D250AD-00 recommendations (220W/250W too low, reported failures)
- Removed LED PSU recommendations (unreliable ripple current)
- Updated minimum power draw: 70W (not 50W, never observed that low)
- Updated minimum PSU requirement: 300W on 12V rail (was 250W)
- Updated cable gauge: 16 AWG minimum (18 AWG has caused melted cables)

Hardware corrections:
- Removed power button header references (board has NO header, solder only)
- Fixed Arctic P12 Pro/Max static pressure: 6.9 mm H2O (was incorrect)
- Added separate specs for P12 Max vs Pro

Documentation cleanup:
- Removed energy cost calculations (as requested)
- Removed multi-board setup sections
- Updated Arch install: direct to Arch Wiki, removed archinstall recommendations

Thanks to DeathStalker and Astrocast for critical safety feedback.